Troubleshooting

If your air conditioner does not work properly, first check the following points before requesting service. If it still does not work
properly, contact your dealer or a service center.

Do not block the air intake and outlet of the unit. If either is obstructed, the

unit will not work well, and may be damaged.

Do not let direct sunlight into the room. Use sunshades, blinds or curtains.

If the walls and ceiling of the room are warmed by the sun, it will take longer to

cool the room.

Avoid

Trouble

Possible Cause

Remedy

Air conditioner does not run at all.

1. Power failure.

2. Leakage circuit breaker has

tripped.

3. Line voltage is too low.

4. Operation button is turned off.

5. The wireless remote controller or

heat pump is malfunctioning.

6. Batteries in wireless remote

controller have run down.

1. Restore power.

2. Contact service center.

3. Consult your electrician or dealer.

4. Press the button again.

5. Consult your dealer.

6. Replace batteries.

Compressor runs but soon stops.

1. Obstruction in front of condenser

coil.

1. Remove obstruction.

Poor cooling (or heating)

performance.

1. Dirty or clogged air filter.

2. Heat source or many people in

room.

3. Doors and/or windows are open.

4. Obstacle near air intake or air

discharge port.

5. Thermostat is set too high for

cooling (or too low for heating).

6. (Outdoor temperature is too low).

7. (Defrosting system does not

work.)

1. Clean air filter to improve the

airflow.

2. Eliminate heat source if possible.

3. Shut them to keep the heat (or

cold) out.

4. Remove it to ensure good airflow.

5. Set the temperature lower (or

higher).

6. (Consult your dealer.)

7. (Consult your dealer.)

Lamps on the indoor

unit are flashing.

1. Trouble in wiring system

1. Contact service center.

Tips for Energy Saving

Always try to keep the air filter clean. (Refer to “Care and Cleaning”.) A clogged

filter will impair the performance of the unit.

To prevent conditioned air from escaping, keep windows, doors and any other

openings closed.

Do

NOTE

Should the power fail while the unit is running

If the power supply for this unit is temporarily cut off, the unit will automatically

resume operation once power is restored using the same settings before the

power was cut off.

Panasonic_PAC-i_IndoorUnit_US-le63 63

Panasonic_PAC-i_IndoorUnit_US-le63 63

2011/11/02 15:17:41

2011/11/02 15:17:41

Advertising
This manual is related to the following products: