Service procedures – Panasonic 36PSU1U6 User Manual

Page 173

Advertising
background image

4-9

4. Service procedures

No

No

No

No

No

No

No

Yes

Yes

Yes

Yes

Yes

Yes

Yes

Replace outdoor unit

control PCB.

(2) [Alarm “P26”]

HIC PCB trouble)

IGBT short-circuit protection on inverter control (IPDU) PCB

Is power OK?

Correct power line.

Are

circuit wiring,

connector

connections, and

reactor

connections

OK?

Correct.

Has filter PCB

RY001 or RY002

relay activated?

Has filter PCB

AC fuse blown?

Replace filter PCB.

Disconnect

U.V.W. output

terminal on HIC PCB and

start operation.

Does alarm

“P26”

occur?

Replace HIC PCB.

Is

compressor OK?

(Check for layer

short circuit.)

Replace compressor.

Is

resistance

between

each terminal on

HIC PCB OK?
(See following

page.)

Check HIC PCB.

Replace if PCB

has failed.

4

SM830203-01_PAC-i_US-letter.indb9 9

SM830203-01_PAC-i_US-letter.indb9 9

2012/01/26 10:32:04

2012/01/26 10:32:04

Advertising
This manual is related to the following products: