Configuration menu - reset to factory defaults, Ds1/dsx-1 24-hour pm threshold – ADC H2TU-C-388 User Manual

Page 28

Advertising
background image

Provisioning

152-388-100-02, Issue 2

20

June 6, 2000

H2TU-C-388 List 1

DS1 BER (DBER) Option.

The DS1 BER alarm occurs when any of the DS1 or DSX-1 performance

monitoring parameters listed in

Table 7

exceed the counts shown for the 24-hour period between 12:00:00 AM

through 11:59:59 PM. These thresholds correspond to a 10

-6

BER. All PM counters clear to zero at 12:00:00 AM

or when Master Clear is selected.

Resetting the H2TU-C

To reset the HiGain Line Unit to its original factory defaults:

1

Type

to select the Config menu.

2

Use the

and

arrow keys to select Set Factory Defaults, then press

.

3

Type

if you are certain you want to reset the H2TU-C, or press

to cancel this action.

Figure 9.

Configuration Menu - Reset to Factory Defaults

Table 7.

DS1/DSX-1 24-hour PM Threshold

Parameter

Threshold Count

CV-L (BPV)

133,400

ES-L, ES-P, PRM-NE, PRM-FE

648

SES-L, SES-P

100

UAS-P, UAS-L

10

Resetting the H2TU-C-388 to its original factory settings may cause interruption of service.

C

ENTER

Y

N

Monitor

Performance

Event Log

Config

Inventory

Rlogon

Help

+----------------------+
| Standard Options ->

|

| PairGain Options ->

|

| Date and Time

->

|

| Master Clear

|

|

Set Factory Defaults

|

+----------------------+

SETTING FACTORY DEFAULTS...SERVICE *MAY* BE INTERRUPTED! ARE YOU SURE (Y/N)?

ID: xxxx--xxxx--xxxx--xxxx

04/15/00 12:30:01

H2TU-C

System: OK