Appendix A - Specifications

152-388-100-02, Issue 2

50

June 6, 2000

H2TU-C-388 List 1

L

OOP

A

TTENUATION

Each loop has no more than 35 dB of loss at 196 kHz, with driving and terminating impedances of 135

(see

Table 19

below).

H

I

G

AIN

L

INE

U

NIT

C

ARD

-E

DGE

C

ONNECTOR

Figure 28

shows the card-edge connectors on the HiGain Line Unit. Active pins are highlighted in black.

Figure 28.

HiGain Line Unit Card-Edge Connector

Network Management Control Bus

The H2TU-C-388 provides a Network Management Control Bus on pin 104 of the card-edge connector. This
allows the various ADC Management System protocols to manage the H2TU-C through the HMU-319 HiGain
Management Unit. Whenever the H2TU-C-388 is under management, the

MNGD

message displays periodically on

the front-panel display.

Table 19.

HDSL2 Cable Attenuation Chart

Cable Gauge

Loss at 196 kHz (dB/kft)

per kft

26/0.4 mm

3.88

83

24/0.51 mm

2.84

52

22/0.61 mm

2.18

32

19/0.91 mm

1.54

16

Some HiGain Line Unit features are affected when it is under management. Consult the
management unit practice for further information.

106

105

104

103

102

101

100

DSX-1 OUT

DSX-1 IN

HDSL2 Span

205

204

203

202

201

200

119

118

117

116

115

114

113

112

111

110

Ground

Ground

Frame ground

Fuse alarm*

Ring 1

Tip 1

Management bus

Ring

Ring 1

Tip

Tip 1

Factory burn-in

-48Vdc

219

218

217

216

215

214

213

212

211

210

209

208

207
206

109

108

107

* Fuse alarm is normally floating (0 to 80 Vdc max.) and

at -48 Vdc (10 mA max.) when activated.