Testing, Front-panel system alarms, Front-panel system alarms summary – ADC H2TU-C-388 User Manual

Page 44: Esting, Ront, Anel, Ystem, Larms

Advertising
background image

Testing

152-388-100-02, Issue 2

36

June 6, 2000

H2TU-C-388 List 1

T

ESTING

This section provides information about front-panel system alarms, LOS and AIS response, OCT55 test
procedure, and loopback testing.

F

RONT

-P

ANEL

S

YSTEM

A

LARMS

Table 14

summarizes all possible HiGain system alarms in order of priority as they appear on the front panel.

When multiple alarms occur, the front-panel display only reports the highest priority alarm. The alarm history
screens display alarms also, but provide greater detail. See

“Using the Performance Screens to View Alarm Data”

on page 30

. All alarms that are not inhibited will drive the front-panel Status LED to a flashing red alarm state.

Table 14.

Front-Panel System Alarms Summary

Front-Panel
Message

(a)

Alarm

Description

To Inhibit

PWR FEED
SHRT

(b)

Power Feed Short

A short exists between the Tip and Ring of
the HDSL2 pair.

Cannot be inhibited.

PWR FEED
GND

(b)

Power Feed Ground

The HDSL2 loop is grounded.

Cannot be inhibited.

PWR FEED
OPEN

(b)

Power Feed Open

A line power open condition exists.

Cannot be inhibited.

LOSW

(c)

Loss of Sync Word

(d)

The HDSL2 loop has lost synchronization.

Cannot be inhibited.

LLOS

(c)

Local Loss of Signal

Loss of the DSX-1 input signal.

Cannot be inhibited.

RLOS

(c)

Remote Loss of Signal

Loss of the H2TU-R DS1 input signal.

Disable the RDA (Remote Disconnect
Alarm) option. The front-panel Status LED
still flashes red and the ALRM RLOS
message displays to alert you of the LOS
state. LOS is sent towards the network
from the H2TU-C. This option prevents the
common occurrences of a CPE LOS
condition from generating recurring
alarms and AIS payloads.

LAIS

Local Alarm Indication
Signal

Indicates an AIS (all ones) pattern is being
transmitted from the local DS1 output
port.

Cannot be inhibited.

RAIS

Remote Alarm
Indication Signal

Indicates an AIS (all ones) pattern is being
received at the H2TU-R DS1 input port.

Cannot be inhibited.

LRAI

Line RAI—Remote
Alarm Indication at the
H2TU-R (Net signal
does not have errors.)

Indicates an RAI alarm (yellow) from the
CPE with an error-free signal from the line
unit or network.

Cannot be inhibited.

RRAI

Remote RAI—Remote
Alarm Indication at the
H2TU-R. (Net signal
has errors.)

Indicates an RAI alarm (yellow) from the
CPE with errors from the line unit or
network.

Cannot be inhibited.

xxxx-DBER

DS1 Bit Error Rate

The DS1 BER has exceeded the set
threshold limits of approximately 10

-6

.

(xxxx denotes either TUC or TUR. If TUC
and TUR occur at the same time, then TUC
displays.)

Select DIS for the DBER system option.

Continued