9-2. F-Functions

‰ “” designates Factory Settings.

F-00-X Weight Unit

‰ Weight Display when the scale is switched on.

See also setting “f-09-01=2”.

0

kg (kilograms).

1

 lb (pounds).

‰ Unit Weight (when “lb” is selected).

0

 lb as piece weight.

1

lb as 1,000 piece weight.

F-01-X Operations

‰ Operation Mode.

0

 Normal Operation. All features and keys available.

1

Simplified Operation. The unit weight registration is by
sample only. All other keys are disabled.

‰ “Add” Sample Request Override.

If the sample weight is too light and the scale asks to “Add”
more sample pieces, using this F-Function, the unit weight
can be entered without adding the requested sample pieces.
Or disable the “Add” Sample Request function.

0

“Add” sample request function is disabled. Light unit weight
can be accepted without “Add” more sample request.

1



The unit weight can be entered without requested “Add”
sample pieces (via the ENTER key).

2

The unit weight cannot be entered without requested “Add”
sample pieces (via the ENTER key).

‰f-01-03” is for factory use and should be “0”.

‰ Display ON Unit Weight – Reset or Last.

When the scale is switched on, the scale can be set to recall
the last unit weight used.

0

 The unit weight is RESET (cleared) when display comes on.

1

The unit weight last used will be entered automatically.

f-01-01

f-01-02

f-01-04

f-00-01

USA Version ONLY

f-00-02