A&D Counting Scale HC-15Ki User Manual

Page 37

Advertising
background image

35

F-06-X RS-232C Data Output

F-06-X requires OP-03 or OP-04 RS-232C interface.

‰ Data Out Mode

0



Key Mode: Data is sent by pressing the PRINT key.
+ Command Mode.

1

Stream Mode: Data is sent continuously.
Command Mode cannot be used.

2

Auto-Print Mode A: Data is sent if the weight display is stable
at +5d (weighing display division) and above.
+ Command Mode.

3

Auto-Print Mode B: Data is sent if the weight display is
stable, at ±5d (weighing display division) and above/below.
+ Command Mode

4

Command Mode Only.

5

To use as Bar Code Reader Interface.

6

UFC format with Key Mode (see setting “0”).

7

UFC format with Auto-Print Mode A (see setting “2”).

8

UFC format with Auto-Print Mode B (see setting “3”).

‰ Data to be Sent.

0100

 Count data sent.

You select which data to be sent by keying in a

0 or 1

for the data: ID no., PCS (count),

weight or unit weight.
Example: Key in 1

1

0

0 to display 1100,

this setting would send only the ID number and
the count.

‰ Data Format

0

 Format for AD-8121 MODE 1.

1

Format for AD-8121 MODE 3.

No difference between “0”
and ”1” when used with the
UFC format.

2

Format for general apparatuses, computers, etc.

‰ Baud Rate

0

 2400 bps.

1

4800 bps.

2

9600 bps.

0000

Weight
PCS(count)

Unit
ID Weight

f-06-02

f-06-04

f-06-01

f-06-03

Advertising