‰ Data Length and Parity

0

 7 bits, even parity.

1

7 bits, odd parity.

2

8 bits, non parity.

‰f-07” and “f-08” are for factory use and should be “0”.

F-09-X ½ key

‰ Operation mode for the ½ key

0



Operating as a key to display and/or change comparator
upper and lower limits.

1

Operating as M-

key to subtract Count data from M+

memory.

2

Operating as a key to toggle the weighing unit between “lb”
and “g”.

‰ Decimal Point and RS-232C Output

0000



Decimal point: “

.

Header for stable weight data: “ST”
Acknowledgment of command: <ACK><C

R

><L

F

>

Select the decimal point “

.

” or ”

,

” and output

format for RS-232C. Set 0 or 1 for each bit.

Decimal point:

“0” = ”

.

“1” = ”

,

Header:

“0” = “ST,+001.2346 kg”

“1” = “WT,+001.2346 kg”

Acknowledgment: “0” = ”<ACK><C

R

><L

F

>”

“1” = ”<ACK>”

‰f-10”, “f-11” and “f-12” are for factory use and should be “0”.

f-06-05

f-09-01

F-09-01=2 is for
USA version
only.

0000

ST/WT
N.A.

Decimal
ACK Point

f-09-02

Advertising