Options Adjustments

Item

Effect Adjustments

Slot Power

Off

Auto

On

Off: Power is not transmitted to the slot power.

Auto: Power is transmitted to the slot power only when main power is on.

On: Power is transmitted to the slot power when main power is on or in the standby state.

Note: In some cases, power is transmitted to the slot power when main power is on or in the standby

state regardless of the slot power setting.

Power On

Screen Delay

Off

1

2

3....

30

You can set the power-on delay time of the displays to reduce the power load, when you press

to turn on the multiple displays that are set together, for example, on MULTI DISPLAY system.

Set each display’s setting individually.

Off: The display will be turned on at the same time as

is pressed.

1 to 30 (sec.): Set the power-on delay time (second).

After pressing

, the display will be powered on with time delay depending on this setting.

Notes:

• During this function is working, the power indicator is blinking green.

• This function also works when the power recovers from failure or after plugging off and in again

the power cord.

After you unplug and plug the power cord in while the unit is in standby mode and also the power

is being supplied to a terminal board, the unit will start supplying the power to the board with time

delay according to the setting.

The power indicator lights up red fi rst and it turns orange when the power starts being supplied

to the board.

V.Installation

Off

On

Off: Sets fan to the horizontal installation mode.

On: Sets fan to the vertical installation mode.

Notes:

• This functions when display is turned on.

• Turn up the power switch for the upward direction when you set Display vertically.

Rotate

Off

On

Off: Does not rotate the image.

On: Rotates the image 180 degrees.

Serial Slot

Select

Slot1

Slot2

Slot3

Selects the slot which communicates serial.

Note: The setting of an external command can be set only from the fi xed serial terminal. (see page 11)

Normalization

When both main unit buttons and remote control are disabled due to the “Button lock”, “Remocon User level” or “Remote
ID” adjustments, set all the values “Off” so that all the buttons are enabled again.

Press the

button on main unit together with

button on the remote control and hold for more than 5 seconds.

The “SHIPPING” menu is displayed and the lock is released when it disappears.