Troubleshooting

Symptom

Possible Cause

Action

Erratic
behavior.

Unit not receiving
enough power.

Use a DC 5V power adapter if you are not

already using one. If you are already using a
power adapter, check that it matches the
system specifications (DC 5V), and that it is
plugged in and functioning properly.

Keyboard
and/or Mouse
not responding.

Keyboard and/or
mouse need to be
reset.

Press and hold port selection switches 1 and 2
for two seconds. (CS-1734

A

only.)

Unplug the cable(s) from the console port(s),
then plug it/them back in.

No connection to the
computer.

Check the cable from the switch to the computer
to make sure it is properly connected.

KVM switch needs

to be reset.

Power off all devices on the installation (see the
note at the top of p. 9); power off the KVM
switch; wait five seconds; then power up.

USB devices
not
responding.

USB ports need to
be reset.

Unplug the device’s USB cable from the USB port
on the switch’s rear panel, then plug it back in.

Use the USB Reset hotkey combination (see p.
18), to reset the USB ports.

Device not
recognized
message
(Windows)

Windows timing
problem.

1. Unplug the KVM cable from the computer’s

USB port.

2. Go into Windows’

System Settings and

remove the

Unknown Device entry.

3. Plug the KVM cable back in. Windows will

now recognize the device.

Sun system
does not start.

CPU port not
configured correctly.

The first time that a Sun system runs from a

port, you must configure its port for the Sun
keyboard operating platform before you turn the
system on, or else the Sun system will not start.
See p. 17 for details.

2005-12-21

CS-1732

A

/ CS-1734

A

User Manual

30