Merrychef eikon e6 User Manual

Page 52

Advertising
background image

E2 SERVICE MANUAL REV D 09/12

52

Error

Code

Oven

Error/Event

Condition

Description

Trigger

Error

Level

System

Response

E122

E2

Radiant Off

Radiant heater
element failed to
turn On

Not Implemented
Yet

Critical

"E122 NO
RADIANT ON
REQUEST"
message is
written to the
error log.

E6

The current
measured by the
SRB is lower than
what is expected.
The calculation is
affected by the

E123

None

Elevator failed

The food elevator
has failed.

The system
determined that
the food elevator is
not operating
correctly.

Critical

"E123
ELEVATOR
FAILED"
message is
displayed in the
error log.

E124

E6

Left Magnetron
overheat

The left
magnetron
thermal switch
has released but
the condition
clears in time

The left magnetron
thermal cut-out has
released while the
left magnetron is
running and the
condition clears

Warning

"E124 LEFT
MAGNETRON
OVER
HEATED"
message is
displayed in the

The left
magnetron
thermal switch
has released but
the condition does
not clear in time

The left magnetron
thermal cut-out has
released while the
left magnetron is
running and the
condition has not

Critical

"E124 LEFT
MAGNETRON
OVER
HEATED"
message is
displayed in the

E125

None

Left Magnetron failed

Left Magnetron
failed to turn On
when requested

The current
measured by the
SRB was outside
of the tolerance
range

Critical

"E125 LEFT
MAGNETRON
FAILED"
message is
written to the
error log.

E126

None

Left Magnetron On
without request

Left magnetron
failed to turn OFF

The left magnetron
current measured
by the SRB was
outside of the
tolerance range

Critical

"E126 LEFT
MAGNETRON
ON WITHOUT
REQUEST"
message is
written to the

E127

E2, E6

QTS board sensor
failed

The temperature
sensor on the
QTS board is no
longer operating

The QTS is
reading an open or
shorted sensor
mounted on the
board

Critical

"E127 QTS
AMBIENT
SENSOR
CIRCUIT
FAILED"
message is