Merrychef eikon e6 User Manual

Page 55

Advertising
background image

E2 SERVICE MANUAL REV D 09/12

55

11

10

4

9

8

7

5

3

2

1

20

24

25

14

15

19

SRB Terminal Locations:

1

X3 - Output for e2 Convection Fan
Controller.

2

X101 - Voltage Selection Relay coil
feeds.

3

X18b – Air Intake Filter Reed (Jumper)

4

X18e – Right Magnetron Thermostat
(Jumper)

5

X18d - Magnetron Thermostat (Top).

6

X18c - Cavity Overheat Thermostat

7

X18a - On/Off Switch

8

X14 - Cavity Temperature
Thermocouple

9

X5 - Fan RPM Input

 

10

X13 - P Bus, Ethernet Port

11

X12 - C Bus, Development PC Port

12

X11 - P/C Bus, QTS Cable

13

X1 - 24V supply from Low Voltage
Transformer

14

X8 - Cooling Fan

15

X17 - Not used.

16

X20 - Microwave Stirrer(s)

17

X9 - Mains Output, Convection Fan
Controller.

18

X103.1 - Mains Output to Low Voltage
Transformer.

19

X103 - Mains Input, Live & Neutral.

20

X2.1 - Mains Input, Live for Heaters.

21

X2.2 - Mains Output, Live to Heaters.

22

X102a - Mains Input, Neutral for
Magnetron Transformers & Monitor
Door Switch.

23

X102b - Mains Output, Neutral to
Magnetron Transformers & Monitor
Door Switch

24

X4a - Door Switch signal from
Secondary Door Switch (Live for
Magnetron Transformers)

25

X10 - Connector Block for door
switches

26

X4b - Live for Magnetron Transformers


1

2

3

4

5

6

7

8

9

12

10

11

13

14

15

16

17

18

19

20

21

22

23

24

25

26