TROUBLESHOOTING

15

4.4. TROUBLESHOOTING

CHART

4.5. CONTROLLER WARNING DISPLAYS
If your applaince is equipped with a temperature controller it may display the following warnings on its
display.

Problem

Probable Causes

Corrective Actions

No power to appliance.

Check main building power supply.

Circuit Breaker tripped.

Reset circuit breaker.

I/0 Switch in 0 position.

Flip I/0 switch to I position and turn on
controller.

Controller not turned on.

Turn on controller.

Controller does not
activate.

Power Cord loose or not connected. Connect power cord.
Water not turned on.

Turn on water.

Autofill does not add
water.

Lower water level sensor is wet.

Dry off sensor.

Dirty upper water level sensor.

Clean upper water level sensor.

Autofill does not shut
off when full.

Insufficient mineral content in water. Add 1/8 cup baking soda to cook tank.

Autofill system has cutoff heat.

Allow Autofill system to fill tank and
restore heat.

Controller displays
that it is heating but
water will not heat.

High temperature limit has tripped

Allow appliance to cool and reset High
temperature limit.

Display

Problem

Action

Water temperature
is low.

Wait for appliance to heat up.

Incorrect probe
reading.

Contact Authorized Service Company.

Water level is low.

Turn off appliance. Allow ample time for appliance to
cool before filling with water and turning on.

Incorrect probe
reading.

Contact Authorized Service Company.

Drain valve is open
while controller is
on.

Turn off appliance. Close drain valve before turning
appliance back on.