INSTALLATION

4

L20-292, rev. 1 (05/11)

1.5.

ELECTRICAL

CONNECTIONS

It is advised that this power supply be plugged into a wall receptacle that is controlled by the
ventilation control. This will prevent the appliance from being operated without the ventilator on. If
your appliance requires an electrical connection, the power requirements are listed below.

CAUTION

Connecting the appliance to the wrong power supply
may damage the appliance and void the warranty.

WARNING

This appliance must be connected to a power supply
having the same voltage and phase as specified on
the data plate located on the inside of the appliance
door.

WARNING

DO NOT attempt to connect the appliance to an electrical supply other then that indicated on
the data plate. Electrical connection should be performed by qualified personnel.

WARNING

The electrical connection used by this
appliance must comply with local codes.
If there are no local codes that apply,
refer to the National Electrical Code
(NEC), ANSI/NFPA 70 for installation in
the US. In Canada, refer to CSA Standard
C22.2 and local codes. In all other cases,
refer to local and national codes and
regulations.

WARNING

The appliance must be grounded in accordance with local code; if there is no local code,
comply with the NEC and ANSI/NFPA No. 70 latest edition (for US and Canadian installations).
In all other cases, refer to local and national codes and regulations. To comply with European
requirements, European models are equipped with an equalization-bonding clamp. An
equalization bonding lead must be connected to this clamp to provide sufficient protection
against potential difference. This clamp, located on the rear of the appliance is marked with
the following universal symbol.

WARNING

A country approved all pole circuit breaker with a
minimum open contact gap of 3mm must be used
for proper installation. (CE countries)

WARNING

This equipment must be installed so that
the plug is accessible unless other means
for disconnection from the power supply
(e.g. a circuit breaker) is provided.

WARNING

If this appliance is permanently connected to fixed wiring, it must
be connected by means of copper wires having a temperature

WARNING

All copper wiring for this appliance must be made in accordance
with the wiring diagram(s) located on the appliance.

To Access

Electrical Connections

Phillips Screwdriver Required

1)

1” (2.54cm) Access Hole

2) Connection

Points

1/2” (1.27cm) Allen
Wrench Required

3) Ground

Connection

Flat head
screwdriver required

Voltage/Phase

KW Amps

200VAC, single phase

7.4

37

208VAC, single phase

8.0

38

220VAC, single phase

8.9

41

240VAC, single phase

10.7

44

200VAC, three phase

7.4

21

208VAC, three phase

8.0

22

220VAC, three phase

8.9

24

240VAC, three phase

10.7

26

346/200VAC, three phase

7.4

12

380/220VAC, three phase

8.9

14

400/230VAC, three phase

9.8

14

415/240VAC, three phase

10.7

15