Vaddio DomeVIEW Flush Mount Dome Installation and User Guide - Document 341-443 Rev C1

Page 4 of 12

Step-by-Step Assembly Instructions:
1) Attach conduit connector to the back of the plenum

rated back can with the provided lock nut.

2) Attach the Safety Bracket to the conduit connector to tie

a safety line up to the building structure if required.

3) All Cabling must be run through this conduit connector

either through conduit or plenum rated cables with all
connectors inside the back can to retain the plenum
rating of the dome enclosure.

4) Thread on the three hex shaped stand-offs (7) on to the

studs in the bottom of the metal back can (8) (See
Figures 3 and 4).














































Figure 2:

Plenum Rated Back Can Assembly

Figure 3:

Exploded View of DomeVIEW Flush Mount Dome for Canon VC-C50iR