Vaddio WallVIEW CCU Z330 User Manual

Page 5

Advertising
background image

WallVIEW CCU Z330

WallVIEW CCU Z330 Installation and User Guide 341-906 Rev. A Page 5 of 12

INSTALLATION
All WallVIEW products are specifically designed for installation on a vertical wall surface with CAT-5 cable
connectivity for Power, Video and Control signaling. Installation is simplified in that no custom 8-Pin mini-din
cables or expensive VGA plenum cables are needed and no power outlets are required near the camera
bracket. All cabling is routed to the head-end using CAT-5 cables.

Before Installing

• Find the appropriate camera mounting location, paying close attention to camera viewing angles, lighting

conditions, possible line of site obstructions, and checking for in-wall obstructions where the camera is to
be mounted. Pick a mounting location to optimize the performance of the camera.

• Pre-wire all cabling as required (see wiring diagram examples).

• The Thin Profile Wall Mount for the WallVIEW CCU Z330 can be mounted directly to a 3-gang wall box

or can be mounted to drywall using four dry wall anchors.



MOUNTING INSTRUCTIONS

Step 1:
After determining the optimum location of the camera system, mark locations for the four screw holes and
cable pass-thru (vertical oval). Install the drywall mounts and cut the hole for the cable pass-thru. At this
point, do not install the Wall Mount.














Step 2:
Connect the 25-pin cable to the EZIM CCU. Next, mount the EZIM CCU and break out cable in the base of
the wall mount, using the two tapped screw holes (see Figure 4).



















Figure 3:
Thin Profile Wall Mount with oval cable feed-
through hole. The wall mount may be mounted
directly to a 3-gang wall box or to drywall with
the appropriate wall anchors.

Note: Z330 Wall Mount looks slightly different.

Figure 4:
25-pin connector mounted to
EZIM CCU (left) and EZIM
CCU mounted to the Wall
Mount (right).

Advertising
This manual is related to the following products: