Interfaces and Functions

32

Beijer Electronics, MAEN956

9.5 Serial Interfaces

The RS232 interface serves for the data communication. Data will be trans-
ferred as ASCII code. The RS232 represents a voltage-referred interface, and is
suited only for short cable lengths by approximately 10-15 meters.

The RS485 bus interface operates as RS422 in opposite clock mode; however
only two lines are needed; these are half duplex. It is possible to connect several
transmitters and receivers via RS485 with the help of a protocol (up to 32 par-
ticipants). The ISO standard 8482 plans a maximum cable length of 500 meters.
The distance between two terminals can be increased with capacity and/or ab-
sorption-poor, in pairs stranded (twisted pair) cable: RS485 supports thus cable
lengths of up to 1.2 km.

Function

Connection between the PC and the monitor to configure, control and read sta-
tus, either point-to-point with RS232 connection, or connection up to 16 mon-
itors in RS485 mode. Functions such as status read (firmware, version, display
ID), control (brightness, backlight, potentiometer) as well as configuration (IP
address, subfunctions of the OSD menu) are available.