9.9 Digital IN

Target Application

The input controls the buzzer or the digital outputs. It can be also used to acti-
vate features e.g. the analog similar dimming. It is also possible to use different
brightness ranges (day, dusk, night) by activating a certain dim value. The exact
function must be programmed into the firmware.

Function

The contacts “Digital IN 1 - 3” are activated by the controller. They can be
linked with the outputs “Digital OUT”, or their conditions can be sent over the
serial or LAN interface.

Plug

4-pin Phoenix plug with “screw safety lock” RM3,81 for lines to 1.5 mm².

Connection

Connection Data

+24 V DC against External GND. Galvanically separated.

Pin

Function

Description

1

IN 1

Digital IN 1

2

IN 2

Digital IN 2

3

IN 3

Digital IN 3

4

GND

External ground