Interfaces and Functions

Beijer Electronics, MAEN956

37

9.8 Analog IN

Target Application

The analog input can be used for dimming by voltage externally put on. The in-
put dims several monitors at one time.

Alternatively an external potentiometer (approximately 10 kohm - 100 kohm)
can be attached as voltage divider.

Function

10 V = full brightness and 0 V = completely dark if the analog input is activated
by the controller.

Plug

3-pin Phoenix plug with “screw safety lock” RM3,81 for lines to 1.5 mm².

Connection

Connection Data

AVOUT constantly 10 V DC (max. 10 mA) against AGND

AIN 0 V – 10 V against AGND

Pin

Function

Description

1

AVOUT

Analog output voltage

2

AIN

Analog In

3

AGND

Analog GND