Hardware Replacement

MODE

Description

1110

Self-test.

xxx1

Hard reset (forces the system to reset).

To change mode switches, follow the steps below:
1. Disconnect power from the operator panel.
2. Set the mode switches using a ballpoint pen.
3. Reconnect power to the operator panel.

7.2 Cables

Most of the operator panels use the same type of flex cable connectors.

connector flanges

Flex cable connector

To release the flex cables from the connector, gently push the two flanges on the
cable connector towards the flex cable.

Note:
The connectors must be unlocked on both sides before removing the cable, otherwise
the flex cable may be damaged.