SANBloc S50 Quick Install Guide

• Liquid has penetrated the server.
• The server has been exposed to moisture.
• The server continues to operate in an unexpected manner even after

solutions suggested in the Administration Guide have been followed.

Installation Cautions and Notes

Caution

To prevent personal injury and equipment damage, have

someone assist you during installation. Ensure the mounting hardware

and tools are easily accessible. If necessary, reduce the weight of the

storage subsystem by removing the drive carriers and APC modules.

Note

Remove all of the components from the packaging and place them

on an antistatic surface until you are ready to use them. If you are using

new disk drives, allow them to acclimate to room temperature before you

install them in the enclosure and power on the system. Before beginning

the installation, inspect the components for shipping damage.

Note

Ensure that your equipment rack is placed in a dust-free, well

ventilated area close to a UPS. Leave enough room behind the rack for

servicing and to allow for sufficient airflow.

Note

For equipment racks with single or multiple storage subsystems

installed, the TMRA (manufacturers maximum recommended ambient

temperature) is 40 °C.

Note

Elevated Operating Ambient Temperature—When installed in a

closed or multi-unit rack assembly, the operating ambient temperature of

the rack environment may be greater than the room ambient. Therefore,

consideration should be given to installing the equipment in an

environment compatible with the manufacturer's maximum

recommended ambient (TMRA).

Note

Mechanical Loading—Prevent instability by installing heavier

items into the bottom of the equipment rack. Mounting of the equipment

in a rack should be such that a hazardous condition is not achieved due to

uneven mechanical loading.