Board Actuator

Function

Cable


Pin 1 Orange

Open Limit

Pin 2 White

Close Limit

Pin 3 Black

Motor (positive on open, negative on close)

Pin 4 Red

Motor (negative on open, positive on close)

Pin 5 Green

Common for both limit switches

Pin 6 Yellow

Feedback from intelligent actuator (816E/816EX)

Pin 7 Black

Battery Negative

Pin 8 Red

Battery Positive

1

3

5

7

2

4

6

8

Actuator Connector



Applies battery voltage directly to motor to open gate if

control board fails. User must unplug before gate opens

to maximum travel or 15 amp fuse will open. Fuse

should be checked before returning gate to service.

EMERGENCY BYPASS (open only)

Connects control board to a computer using

GateLink

software. This software

can monitor and diagnose the functions of the microprocessor. Ask your sales-
person about this feature.

GateLink

Connector

12V

Supplied battery voltage


SLV

Slave Operator Indicator (indicates slave side of gate is closed)

+12V when on closed limit. Ground when off of closed limit.

MAS

Master Operator Indicator (indicates master side of gate is closed)

+12V when on closed limit. Ground when off of closed limit.

GND

Battery supplied ground


SIREN Connect to siren +

applies +12V when gate(s) are running, or in hard shutdown


GND

Battery supplied ground


LOCK Connect to lock + (optional) Magnetic or Solenoid type locks (Dip Switch #6 Selectable)

Remote Outputs