Optional device inputs – Apollo 1650ETL User Manual

Page 17

Advertising
background image

17

GND

Supplied Battery Ground


INP

Activate Gate (Push button activation when momentarily shorted to ground)


12V

Supplied Battery Voltage (Protected with 3 Amp fuse)

GND

Supplied Battery Ground


INP

Activate Gate (Push button activation when momentarily shorted to ground)


12V

Supplied Battery Voltage (Protected with 3 Amp fuse)

EDGE Reverse edge input. When grounded, will stop and reverse gate if closing, resets close timer if gate is open.

EDGE
Reverse edge input. When grounded, will stop and reverse gate if closing, resets close timer if gate is open.

GND

Supplied Battery Ground


GND

Supplied Battery Ground


STOP Stop input from a 3 button station (must remove STOP CIRCUIT JUMPER) Normally closed

CLOSE Close input from a 3 button station (see program switch #5 for options)

OPEN Open input from a 3 button station (see program switch #5 for options)

GND

Supplied Battery Ground


GND

Supplied Battery Ground


FREE EXIT Opens gate if closed, stops and reverses gate if closing, resets close timer if gate is open.

GND

Supplied Battery Ground


SHADOW Resets close timer when gate is open (also referred to as under gate loop)

GND

Supplied Battery Ground


SAFETY Resets close timer if gate is open, stops and reverses if gate is closing. (Does not open a closed gate)

GND

Supplied Battery Ground


FIRE

When grounded, opens gate and holds gate open until released.

Clears “Hard Shutdown” mode of software.

UL

When grounded, opens gate and holds gate open until released.

Clears “Hard Shutdown” mode of software.

Optional Device Inputs

GND

Supplied Battery Ground


INP

Activate Gate (Push button activation when momentarily shorted to ground)


12V

Supplied Battery Voltage (Protected with 3 Amp fuse)