Program Switches

OFF ON

1 TIMER TO CLOSE

Gate does not automatically close.

Gate automatically closes.


2 TIMER TO CLOSE OPT.

Gate automatically closes from

Gate automatically closes only when completely

any position after opening.

open (open limit engaged).


3 SLAVE DISABLE

Enables slave side (dual gate use).

Disables slave side. (single gate use)

4 SIREN DELAY

Siren (optional) active when gate is

Siren (optional) starts 5 seconds before gate moves.

moving.


5 ‘STOP’ CIRCUIT ENABLE
Must hold down open or close

Normal operation

buttons to move gate. Gate stops

Momentary open or close input runs gate to limit.

when

button

released.


6 LOCK TYPE

For 12V mechanical (solenoid) locks. For 12V magnetic locks.

(+12V for 4 seconds on open cycle)

(+12V when on close limit)

7 COAST ENABLE

Gate will stop immediately when at

Gate will coast (minimally) when it reaches limits.

Open or Close limit

Recommended for 7500 slide operator only.


8 FREE EXIT OPT.

A free exit input will open gate from

A free exit input will open gate from any

closed position or after a close cycle

position after an open or close cycle.

only.


9 DUAL GATE SYNC

Both gates operate at normal

This feature will control the master gate to open

Speed (slave slower than

or close at the same speed as the slave gate.

Master).

10 SMART ACT.

Off for 416E & 416EX actuators,

Used for 816E & 816EX actuators only

slide gates, 3500 or when slow down

(soft start & stop).

feature

is

not

desired.