15

Adjustments

Push Buttons

TIMER TO CLOSE

Adjusts time before gate automatically closes

Adjustable 5 to 70 seconds.


DUAL GATE DELAY Adjusts delay between master and slave op-

eration 0-4 seconds (836 only for use with

magnetic, solenoid, and other locking de

vices)

CURRENT SENSITIVITY
Increases or decreases the Auto Reverse
sensitivity.

LED ENABLE When depressed, activates LEDs for 15

minutes to assist in installation and troubleshooting.

Hold the push button down for five seconds to put

the board in program mode.

RESET

Resets the microprocessor. Returns processor to

last

known

state.

OPERATE

When depressed, activates the gate. Used for initial

installation

and

testing.

Hard Shutdown Reset Resets the operator when the gate current

senses twice before fully opening or closing.

Jumpers

STOP CIRCUIT JUMPER

When the STOP CIRCUIT

program switch #5 must be ON

JUMPER is connected, the gate

will

operate

normally.

STOP CIRCUIT JUMPER

When a 3-button station is con-

program switch #5 must be OFF

nected to the board, the STOP

CIRCUIT

JUMPER

must

be

re-

moved.