Meteor ProMover 250 User Manual

Page 6

Advertising
background image

6

Lamp adjustment
-

The lamp holder is aligned at the factory. Due to differences between lamps, fine
adjustment may improve light performance.

-

Strike the lamp, open the shutter, and set the dimmer intensity to 100 % and focus the light
on a flat surface (wall).

-

Center the hot-spot (the brightest part of the beam) using the 3 adjustment screws "A, B,
C". Turn one screw at a time to drag the hot-spot diagonally across the projected image. If
you cannot detect a hotspot, adjust the lamp until the light is even.

-

To reduce a hot-spot, pull the lamp in by turning all three screws "A, B, C" clockwise 1/4-
turn at a time until the light is evenly distributed. If the light is brighter around the edge than
it is in the center, or if light output is low, the lamp is too far back in the reflector. "Push" the
lamp out by turning the screws "A, B, C" counterclockwise 1/4-turn at a time the light is
bright and evenly distributed.

Overhead Rigging if the main attachment fails as a secondary back-up

DANGER TO LIFE!

-

Please consider the DIN 15560 and the respective national norms during the installation!

-

An authorized dealer must only carry out the installation!

-

The installation of the device has to be built and constructed in a way that it can hold 10
times the weight for 1 hour without any harming deformation.

-

The installation must always be secured with a secondary safety attachment, e.g. an
appropriate catch net.

-

This secondary safety attachment must be constructed in a way that no part of the
installation can fall down

-

When rigging or derigging or servicing the device staying in the area below the installation
place, on bridges, under high working places and other endangered areas is forbidden.

-

The operator has to make sure that safety-relating and machine-technical installations are
approved by an expert before taking into operation for the first time and after changes
before taking into operation another

-

The operator has to make sure that safety-relating and machine-technical installations are
approved by an expert after every four year in the course of an acceptance test.

-

The operator has to make sure that a skilled person approves safety-relating and machine-
technical installations once a year.


Procedure:
-

The device should be installed outside areas where persons may walk by or be seated.
IMPORTANT!
OVERHEAD RIGGING REQUIRES EXTENSIVE EXPERIENCE, including (but not limited
to) calculating working load limits, installation material being used, and periodic safety
inspection of all installation material and the device. If you lack these qualifications, do not
attempt the installation yourself, but instead use a professional structural rigger. Improper
installation can result in bodily injury and or damage to property.

-

The device has to be installed out of the reach of people.

-

If the device shall be lowered from the ceiling or high joists, professional trussing systems
have to be used.

-

The device must never be fixed swinging freely in the room.

Caution: Devices in hanging installations may cause severe injuries if not properly
mounted and secured correctly with appropriate back-up “failsafe rigging”.