Using the gui – Australian Monitor AMD200 User Manual

Page 11

Advertising
background image

Priority:

The Priority window allows you to adjust which inputs have priority over others.
There are four levels of priority in the AMD Series.

Level 0 – No Priority

Level 1 – Low Priority

Level 2 – Medium Priority

Level 3 – High Priority

Level 4 – Highest Priority

When two inputs share the same level of priority they will both stay active when
the lower priority channels mute.

The threshold at which the priority will become active is adjusted via the control
at the top of the page.

All inputs will trigger from the same audio level set from the priority threshold control.

Bell and Chimes have selectable priority and can sit on any of the 5 levels.

Evac and Alert are fi xed to the highest level of priority.

BGM sources are fi xed to the lowest level of priority.

Tones:

The tone generator window allows you to adjust the volume of the tones
present in the AMD Series. The following tones are available:

Bell (Pre Master Level)

Chimes (Pre Master Level)

Alert (Post Master Level)

Evac (Post Master Level)

All tones volumes are by default set to -12 db.