Input Level:

Each input on the AMD100/200 contains a digital trim level control, this ranges
from -96 dB to +12 dB.

There is also an invert button to reverse the phase on that input.

Input Dynamics:

Each input on the AMD100/200 contains a compressor. Threshold, Ratio, Attack,
Release and Output Gain may be adjusted.

All adjustments are displayed on the graph to the right of the screen.

Input EQ:

Each input on the AMD100/200 contains EQ. The EQ features a Low Shelf, High Shelf
and 2 parametric fi lters.

All adjustments are displayed on the graph to the right of the screen.

Output EQ/Filter:

Each output of the AMD100/200 contains an EQ and Crossover. The crossover allows
you to place a High Pass, Low Pass and All Pass fi lter on the signal. Each fi lter has a
frequency adjustment, the All Pass fi lter also contains a Q width adjustment.
From the drop down boxes below the fi lter adjustments you can change the fi lter slope,
the options are:

Butterworth 6 dB/Oct – 24 dB/Oct

Linkwitz-Riley 12 dB/Oct – 24 dB/Oct

Bessel 12 dB/Oct – 24 dB/Oct

The EQ section of the output features a High Shelf, Low Shelf and 4 parametric fi lters.

Both the crossover and the EQ section displayed on the graph to the right of the page.