Current control for quadpack, Rs 232-interface on the motor connector side, How to obtain the connectors – RMS Technologies 4-AXIS CONTROLLER/DRIVER User Manual

Page 10

Advertising
background image

10

S I X P A C K / Q U A D P A C K

Trinamic Motion Control GmbH & Co KG

Sternstraße 67

D – 20357 Hamburg, Germany

Phone +49-40-51 48 06 - 0

FAX: +49-40-51 48 06 - 60

http://www.trinamic.com

Current Control for QUADpack

The maximum coil current for the QUADpack can be set in steps of 0mA (0%), 500mA (33%),
1000mA (66%) and 1500mA (100%). A fine adjustment is done by software.

Motor

1 2 3 4

Dip-SW

1 2 3 4 5 6 7 8

I=100% ON ON ON ON ON ON ON ON

I=66% OFF ON OFF ON OFF ON OFF ON
I=33% ON OFF ON OFF ON OFF ON OFF

I=0 OFF OFF OFF OFF OFF OFF OFF OFF

RS 232-Interface on the Motor Connector Side


Type of connector: ribbon cable-connector for 10-pin header with 2,54 mm pitch

How to obtain the Connectors

AMP Connectors (for motor and reference inputs)
order number:

0-0770602-8 (Case)

0-0770666-1

(Crimp contact)

0-0058517-1

(Crimp

tool)



TXD

RTS

GND

TTLOUT1

(270 OHM)

5V (120mA)

1

2

3

4

5

6

7

8

9

10

TTLIO1 (270 OHM)

Analog In 7 (0..5V)

GND

CTS

RXD

PCB edge

Advertising