Velocity, Acceleration

(amax and vmax are checked permanentely, the Pack promptly reacts to changes)

CMD

$14

P0

motnr (0...5)

P1,2 #

amax (1..32767): max. motor acceleration
1/64 amax is accumulated with 500Hz during acceleration to vact: Beginning with
vstart the motor is accelerated until vmax has been reached.

0 < amax <= vstart * 64 (default: amax =128)

P3,4 #

vmax (1..511): Maximum value for vact

vmax <= 511