8.5 Additional Inputs / Outputs

Read Motor Input Channels and additional Inputs

The analogue channels are prepared for ratiometric measurements of resistive dividers. Channel 6 is
the external input, channel 7 measures the voltage supply of the PACK (1V equals value 22). The
reference inputs are inverted.

CMD

$30

P0

channel no (0=channel0 ... 7=channel7).

P1 response

address

Response
CMD $30
P0

channel no (0...7).

P1,2 #

analogue value (unsigned 0..1023)

P3

reference input (Bit 0)

P4

all reference inputs / jumpers (bit 0 = motor 0, ..., bit 6=jumper1, bit 7 = jumper2)
(s. setting the baud rate)

P5

bit 0: logic state at TTLIO1

Setting the Limits for the Stop Function left/right

A potentiometer or a resistor network connected to two stop switches at the analogue input of each
motor can trigger a hard or soft stop. The voltage of the analogue input should increase in right
direction (cw). The measured value is checked dependent on the motor direction. When a stop-
condition occurs the motor is stopped immediately. If StopSoft-Flag is set, the motor is in decelerated
with the pre-set acceleration. If the StopSoft Flag isn’t set the motor will be stopped abruptly, so that
the precise motor position may be lost. Therefore a reference search will be started additionally if the
StopNoRef-Flag is not set. When the StopNull-Flag is set, the zero switch also functions as a limit
switch. If the reference switch is defined on the right side, the motor then can only drive in the area of
negative co-ordinates

(position <= 0)

(s. CMD $15)

CMD

$31

P0

channel no (0...7):

P1,2 #

analogue value minimum for stop left (0=no function)

P3,4 #

analogue value maximum for stop right (

≥1023=no function)

Setting of additional Outputs

CMD

$32

P0

bit 0: set logic level at TTLOUT1 (1=READY, 0= active)

P1

bit 0: output enable for TTLIO1 (1=input, 0=output)

P2

bit 0: set logic level at TTLIO1

P3

bit 0: 1=TTLOUT1 works as ready output (1=READY, 0= active)