SawStop 10” Industrial Cabinet Saw 77

Electrical Schematic — 230V, Single-Phase (3 and 5 HP)

1L1

3L2

5L3

13NO

14NO

2T1

4T2

6T3

2T1

4T2

6T3

95

96

A2

COIL

A1

COIL

GROUND PLA

TE

NOISE

FILTER

TO

MOTOR

TO

SWITCH BOX

MAGNETIC

CONTACTOR BOX

DISCONNECT

SWITCH

SURGE

SUPPRESSOR

CONNECT 208-240V

1-PHASE POWER HERE

CONNECT EQUIPMENT

GROUND HERE

TERMINAL BOX

NO

N C

COM

NO

NC

COM

MOTOR COVER

INTERLOCK SWITCH

DO NOT

USE*

*This saw does

not require a neutral line.

SawStop recommends the use of a 3-wire cable or

conduit, with the black and white wires connected

to power and the green wire connected to a

grounded metal permanent wiring system or

equipment ground.
If a 4-wire cable or conduit with a neutral wire is

used, the neutral line should be capped with a wire

nut or connected to the unused center terminal.

BELT ACCESS DOOR

INTERLOCK SWITCH

Black

Green

Green

Green

Green

Red

White

White

White

White

White

Blue

Yellow

White

Black

Black

Black

Black

Black

Black

Green

Green / Y

ellow

Black

Black

White

Black

Black

Black

White

White

Black

White

Black

Black

White

97

98

Cabinet Saw Manual 1st Reprint.i77 77

3/9/2010 8:33:11 AM

Advertising