Kramer Electronics VP-774 User Manual

Page 74

Advertising
background image

VP-774 - The VP-774 RS-232 Communication Protocol

69

69

1st
Level

2nd Level

3rd Level

4th Level

Range

Func. Note

Group D

None

0 (read only)

294

Activate CH1

1

Activate CH2

2

Bypass

3

Bypassed Group

Unmute

0

295

Mute

1

Process

Deinterlacing

Method

Line Doubler

0

311

Volatile parameter
unavailable in
progressive scan

Motion Adaptive 1

Sync

Current Field

0

312

Unavailable in
progressive scan.

Older Field

1

Film Mode

Off

0

320

Unavailable in
progressive scan

Follow Input

1

24PsF Mode

2

Diagonal
Correction

0:3

330

Unavailable in
progressive scan.
Unavailable when
deinterlacing sync is
older field

MD Sensitivity

LEVEL1

0

340

Unavailable in
progressive scan

LEVEL2

1

LEVEL3

2

LEVEL4

3

LEVEL5

4

Picture

Brightness

-400:400

410

In the OSD menu
the range appears
as -80:80

Contrast

0.1:1.6

420

Color

0.1:1.6

430

Color
Correction

Blue

0:4

441

Green

0:4

442

Flesh

0:4

443

Black Level

-80:80

450

Gamma Mode Gamma Off

0

460

Gamma 0.4

1

Gamma 0.8

2

Gamma 1.2

3

Gamma 1.6

4

Gamma 2.0

5

Gamma 2.4

6

Gamma 2.8

7

Dither

Mode0: Disable error diffusion

0

470

Mode1: In-frame 8:6 conversion

1

Mode2: Intra-frame 8:6 conversion

2

Mode3: In-frame 10:8 conversion

3

Mode4: Intra-frame 10:8 conversion

4

Mode5: In-frame 12:10 conversion

5

Mode6: Intra-frame 12:10 conversion

6

Auto Adjust

0:1

480

Self-clearing

Advertising