Kramer Electronics VP-774 User Manual

Page 81

Advertising
background image

76

VP-774 - The VP-774 RS-232 Communication Protocol

Operation commands

Command

Syntax

Response

115200

DATA_BITS = 5 to 8 inclusive

PARITY

= “NONE”, “ODD”, “EVEN”, “MARK”, “SPACE”

or the first letter of these words

STOPBITS = 1 or 2



Audio/video common commands

Command

Syntax

Response

Output volume

VOLUME VOLUME-

PARAMETER

VOLUME VOLUME-

PARAMETER RESULT

Get output volume

VOLUME?

VOLUME VOLUME-VALUE

Parameters Description:

VOLUME-PARAMETER

= output volume parameters:

[VALUE] either positive or negative digits (minus sign precedes negative values).
“+” increase current value,
“-“ decrease current value
Windows
customization

WIN-CUST WINDOW, HPOS,

HW , VPOS, VH

WIN- CUST WINDOW, HPOS,

HW , VPOS, VH RESULT


Parameters Description: fast window customization
[WINDOW] “0” for main window; “1” for PiP window
[HPOS] horizontal position value
[HW] horizontal width value
[VPOS] vertical position value
[VH] vertical height value

Set dual window state

PIP PIP-MODE

PIP PIP-MODE RESULT

Get dual window state

PIP?

PIP PIP-MODE

Parameters Description:

PIP-MODE

= Dual window state:

"0" or "off" for single window.
"1" or "on" to for dual window.


Identification commands

Command

Syntax

Response

Protocol
Handshaking

#CR

~OK CRLF

Read device model

MODEL?

MODEL MACHINE_MODEL

Read device serial
number

SN?

SN SERIAL_NUMBER

Read device
firmware version

VERSION?

VERSION MAJOR .MINOR
.
BUILD .REVISION


Read device build
date

BUILD-DATE?

BUILD-DATE YYYY/MM/DD

Advertising