VP-774 - The VP-774 RS-232 Communication Protocol

75

75

Operation commands

Command

Syntax

Response

Power state

POWER POWER-MODE

POWER POWER-MODE

RESULT

Get power state

POWER?

POWER POWER-MODE

Parameters Description:

POWER-MODE

= power state:

"0" or "off" to enter standby mode.
"1" or "on" to power up.

Restart device

RESET

RESET OK

Peripheral firmware
update execute*

UPGRADE

UPGRADE OK

Usually the firmware will upload to the device via a command such as LDFW
A device reset may be needed to complete the process

Video core Firmware
update execute*

UPGRADES

UPGRADES OK

Reset configuration
to factory default

FACTORY

FACTORY RESULT

SET dedicated EAS
port settings

EAS-CFG PORTTYPE,

PORTNUM

EAS-CFG PORTTYPE,

PORTNUM RESULT

GET dedicated EAS
port settings

EAS-CFG?

EAS-CFG PORTTYPE,

PORTNUM

Parameters Description:

PORTTYPE

either “TCP” or “UDP”

PORTNUM Ethernet port

EAS Activation Mode
notification
messages

N/A

EAS-EXE ACTIVATION-MODE OK

Parameters Description:

ACTIVATION-MODE

= EAS notification:

“1” to notify full screen + siren activation mode (Severity = Extreme)
“2” to notify full screen activation mode (Severity = Severe)
“3” to notify crawler activation mode (Severity = Moderate \ Minor \ Unknown)
“0” to notify that the alert went off either by timeout or by keystroke
SET dedicated port
tunneling settings

PTNL-CFG PORTTYPE,

PORTNUM

PTNL-CFG CFG PORTTYPE,

PORTNUM RESULT

GET dedicated port
tunneling settings

PTNL-CFG?

PTNL-CFG PORTTYPE,

PORTNUM

Parameters Description:

PORTTYPE

either “TCP” or “UDP”

PORTNUM Ethernet port

SET UART port tunneling
settings

UART BAUD,

DATA_BITS, PARITY,
STOPBITS

UART BAUD, DATA_BITS,

PARITY, STOPBITS RESULT

GET UART port tunneling
settings

UART?

UART BAUD, DATA_BITS,

PARITY, STOPBITS

Parameters Description:

BAUD = 1200, 2400, 4800, 9600, 19200, 38400 57600,