Kramer Electronics VS-88HCB User Manual

Page 17

Advertising
background image

KRAMER: SIMPLE CREATIVE TECHNOLOGY

Connecting the VS-88HCB

14

6.3 Controlling via RS-485

You can control a

VS-88HCB unit via an RS-485 controller

1

, for example, a

PC (equipped with an RS-485 interface) or a Master Programmable Remote

Control system, such as the Kramer

RC-3000.

To connect an

RC-3000 to a single VS-88HCB unit (see Figure 8):

1. Connect the RS-485 terminal block port on the

RC-3000 to the RS-485 port on

the

VS-88HCB unit, as follows:

Connect the “A” (+) PIN on the RS-485 rear panel port of the

RC-3000 to the “A” (+) PIN on the RS-485 rear panel port of the

VS-88HCB unit

Connect the “B” (-) PIN on the RS-485 rear panel port of the

RC-3000 to the “B” (-) PIN on the RS-485 rear panel port of the

VS-88HCB unit

If shielded twisted pair cable is used, the shield may be connected to

the “G” (Ground) PIN on one of the units (for example, on the

RC-3000)

2. Set the SELF ADDRESS # dipswitches on the

VS-88HCB unit to a SELF

ADDRESS # between 2 and 8, according to section 6.5.1. Do not set as SELF

ADDRESS # 1 (the Master). Terminate the RS-485 line on both the

VS-88HCB unit (set DIP 4 to ON) and on the RC-3000

2

.

Figure 8: Controlling via RS-485 (for example, using an RC-3000)

1 RS-485 can be used for control even for distances exceeding 1km
2 Refer to the RC-3000 user manual for details of how to terminate the RS-485 line