6.1.1 Determining the Machine Number

Each unit must be identified by a unique Machine #. Determine the
Machine #

according to

Table 3

.

• When using a single unit, set the unit to Machine # 1.
• A master unit must be Machine #1.

When connecting more than one VS-88SDI unit, set a different Machine #
on each unit. The units do not have to be numbered sequentially but each
unit must have a unique machine number.

Table 3: Machine # DIP-Switch Settings

Machine #

DIP-SWITCH

1

2

3

4

1 (Single or

master unit

1

OFF

ON

)

OFF
OFF

OFF
OFF

OFF
OFF

2

OFF

ON

OFF

OFF

3

ON

ON

OFF

OFF

4

OFF

OFF

ON

OFF

5

ON

OFF

ON

OFF

6

OFF

ON

ON

OFF

7

ON

ON

ON

OFF

8

OFF

OFF

OFF

ON

9

ON

OFF

OFF

ON

10

OFF

ON

OFF

ON

11

ON

ON

OFF

ON

12

OFF

OFF

ON

ON

13

ON

OFF

ON

ON

14

OFF

ON

ON

ON

15

ON

ON

ON

ON

Note: After changing the address, the device must be reset by turning OFF
and ON.

6.1.2 Setting the DIP-Switches

When controlling a unit via the RS-232 or RS-485 ports set the
DIP-switches on the rear of the unit.

Figure 3

and

Table 4

define the

DIP-switches

2

1 A single or master unit can have the address 0 or 1

:

2 The default address is 0 (all DIP-switches are OFF)