2 connecting a pc or controller to the rs-485 port, 1 setting the address switches, Connecting a pc or controller to the rs-485 port – Kramer Electronics VS-88SDI User Manual

Page 16: Setting the address switches, Figure 3: dip-switch settings, Table 4: dip-switch settings, Figure 3, Table 4

Advertising
background image

KRAMER: SIMPLE CREATIVE TECHNOLOGY

Connecting the VS-88SDI

12

Figure 3: DIP-Switch Settings

Table 4: DIP-Switch Settings

DIPS

Function

Description

RS-485 Term

RS-485 line termination

OFF for no RS-485 line termination

ON for RS-485 120

Ω line termination

PROG

Firmware update

Set ON only to update device firmware

MACH # 1, 2, 3, 4

Self Address

Sets the MACHINE # (see section

6.1.1

)

The RS-485 TERM DIP-switch is used only when the RS-485 port is
connected (see section

6.2.2

). The first and last units on the RS-485 line

(for example, the controller and the last VS-88SDI) must be terminated;
the units in between must not be terminated.

Set the PROG DIP-switch ON only while updating the unit firmware,
otherwise the switch must be OFF.

6.2

Connecting a PC or Controller to the RS-485 Port

You can operate the VS-88SDI via the RS-485 port from a distance of up to
1200 meters (3900ft) using any device equipped with an RS-485 port (for
example, a PC). For successful communication, you must set the RS-485
machine number and bus termination.

To connect a device with a RS-485 port to the VS-88SDI:

• Connect the A (+) pin on the RS-485 port of the PC to the A (+) pin on

the RS-485 port on the rear panel of the VS-88SDI

• Connect the B (–) pin on the RS-485 port of the PC to the B (–) pin on

the RS-485 port on the rear panel of the VS-88SDI

• Connect the G pin on the RS-485 port of the PC to the G pin on the

RS-485 port on the rear panel of the VS-88SDI

6.2.1 Setting the Address Switches

To set the address DIP-switches:
• Assign Master Machine #1 to the master unit with the address

0 or 1 set in the DIP-switches

• Assign a unique Machine # from 2 to 15 for each VS-88SDI slave

unit using

Table 3

. The units do not have to be sequentially

numbered but they must have unique addresses

Advertising