Communication Parameters

22

9

Communication Parameters

The following table lists the communication parameters for Protocol 2000

and Protocol 3000.

Table 7: Communication Parameters

RS-232
Protocol 2000

Protocol 3000 (Default)

Baud Rate:

9600

Baud Rate:

115,200

Data Bits:

8

Data Bits:

8

Stop Bits:

1

Stop Bits:

1

Parity:

None

Parity:

None

Command Format:

HEX

Command Format:

ASCII

Example (Output 1 to Input

1):

0x01, 0x81, 0x81, 0x81

Example (Output 1 to Input

1):

#AV 1>1<CR>

Switching Protocol
P2000 -> P3000

P3000 -> P2000

Command:

0x38, 0x80, 0x83, 0x81

Command:

#P2000<CR>

Front Panel:

Press and hold Output 1 and

Output 2 simultaneously

Front Panel:

Press and hold Output 1 and Output 3

simultaneously

Ethernet
Default Settings

Reset Settings

IP Address: 192.168.1.39

Power cycle the unit while holding in the Factory Reset

button, located on the rear panel of the unit.

TCP Port #: 5000
UDP Port #: 50000

10 Using the P3K Wizard

P3K is a Kramer software program for accessing and changing device

parameters and upgrading the machine firmware. The P3K program can be

downloaded from the Kramer Web site at

www.kramerelectronics.com

.

10.1 Changing the Device Parameters

To change the device parameters do the following:

1. Connect a PC to the

VS-88SDI using any one of the following connections:

• Connect a serial cable from an RS-232 9-pin D-sub rear panel

port on the PC to the

VS-88SDI as explained in section

6.1

.

• Connect an RJ-45 Ethernet cable from the Ethernet port on the

PC to the Ethernet port on the

VS-88SDI.

Advertising