The kramer rc configuration main window – Kramer Electronics RC-8iR User Manual

Page 29

Advertising
background image

The Kramer RC Configuration Main Window

25

#

Feature

Function

6

Front Panel Tab

Shows the layout of the RC buttons according to the device type

selected, with the labels on the button. Click to Select a button to
configure, modify, read, or delete its macro.

When the button is:

• Blue, it is assigned a macro
• Green, it is selected
• Gray, it is not assigned a macro

7

Event Macros Tab

By default, two event macros are assigned and can have commands

added to them:

Startup – a series of commands to be executed when the machine is

turned on

Inactivity timeout – a series of commands to be executed after a set

amount of inactivity time (during which no button is pressed) has
expired (see

Figure 24

)

8

Button Area

1

Label Text Box

Select a button and type the required button label

9

Behavior Drop

Down Box

Assign the button response to press and release actions

Button Definition

Behavior

Activate on Release

(default)

The macro is executed upon releasing the button

Activate while

Pressed

The macro is activated and repeated for as

long as the button is pressed

Hold for 2 seconds

Press and hold the button for 2 seconds to

execute the macro

Toggle 1-2-3-4

Cycling macro behavior:
The button can be assigned with up to 4

different macros. Each time it is pressed, the
next macro in the set will be activated in a cyclic
fashion

2

, provided the Automatic Advance box

is checked (the default). If the automatic
advance button is not checked, the macros will
advance only as part of a macro sequence in a
different button (see section

10.2.4

)

Toggle Press-

Release

Dual macro behavior:
One macro is activated when pressing the

button and the other is activated when
releasing the button

Disabled

The button is disabled

10 Write Configuration Button

3

Press to write the configuration of all the buttons to the device

11 Read Configuration Button

3

Press to read the configuration of all the buttons from the device

12 Response querying Area

(shows after checking this option
in the configuration menu, see
section

11.3

)

Enabled for RS-232, RS-485 and Ethernet communication
Wait for response Check Box – check for the command to wait for a

response before continuing with the macro

Max. … Seconds– type the response wait timeout in seconds (from

0 to 999 seconds)

Check for specific response Check Box – specify an exact response

to wait for (otherwise any response will do)

If there is no response or the response doesn’t match, the button will

flash and the macro will be aborted

1 The Button area appears only after selecting a button in the Front Panel tab

2 The number of toggle states can be determined (from 1 to 4). The selected number of toggle states appears above the Button

Macro area (see

Figure 25

)

3 This button is enabled only when a device is connected to the PC. Otherwise it is disabled

Advertising