The Kramer RC Configuration Main Window

26

#

Feature

Function

Button Macro Area

13 Button Macro Display Box

Displays the macro RC commands’ Description, Delay and Port in

sequence. Select an RC command to duplicate, delete, or change its
position in the sequence

New Command Button

Click to add a new command to the Button Macro display box

1

(see

section

10

)

Duplicate Command Button

Duplicate a command in the Button Macro display box

Delete Command Button

Delete a command from the Button Macro display box

Button

Move up the selected command

Button

Move down the selected command

14 RC command Area

Includes the following features of the command selected in the

Button Macro display box:

Description Text Box

Optional descriptive text for the command

Port Drop Down Box

Displays the port associated with the RC command:
Select a port when modifying or writing a new RC command.
When selecting an IR port, a serial port, or an Ethernet port, the

Vendor, Device, Revision and Driver command drop down boxes
appear, as well as the Port default driver box and an Update button to
update the port default driver. The command bytes box appears for the
serial and Ethernet ports.

When selecting a relay port, the Relay command drop down box

appears.

Vendor Drop Down Box

Displays the current vendor. Select the vendor when writing a new

RC command or modifying a selected command

Device Drop Down Box

Displays the device driver name. Select the device driver when

modifying or writing a new RC command

Revision Drop Down Box

Displays the device driver revision. Select a revision when modifying

or writing a new RC command

Driver command Drop Down

Box

Displays the current driver command. Select a driver command

when writing a new command or modifying a selected command

Relay command Drop Down Box Select the Relay command:

Open – N.C. and Common are connected (default)
Close – N.O. and Common are connected

Port default driver Box and

Update Button

The port default driver box shows the current port default driver. It can

be updated by setting a different driver through the RC command and
then clicking the Update button (see section

8

)

Command bytes Box

Displays the command bytes

15 Button lighting Area

2

Select the buttons that will illuminate, turn dark or remain the same

following a command (the lighting configuration can be different for each
command within the sequence). Toggle between ON (yellow), OFF
(black) and No Change (gray). You can also click reset to reset the
buttons to No Change (gray)

16 Delay after command Text Box

2

Set a delay time in seconds or milliseconds following the command

3

1 The button macro display box displays <No Description> under Description and None under Port

.

The delay between the commands can be set from 0.01 seconds up to
640 seconds. Also, multiple commands with delays can be cascaded to
create a longer delay, if required, up to about 2.5 hours (15 delays of 10
minutes each).

2 Shows after checking this option in the configuration menu (see section