Genlock – Kramer Electronics SP-14 User Manual

Page 11

Advertising
background image

11

2.3.

Genlock

Vertical frame synchronisation is provided. The frame signal can be derived from the dedicated
analogue Genlock input as a bi or tri-level sync or from the dedicated 3G-SDI Genlock input. The frame
synchronisation signal must be a video format and must have a vertical rate of 50Hz, 59.94Hz or 60Hz.
The output will be vertically locked to the frame synchronisation signal at the exact same rate. The
phase can be controlled through the menu system, allowing adjustment for a desired latency.

Frame synchronisation status is shown via the front panel status indication on the right-hand side of the
screen, provided it has been enabled on the menu.