Rst synchronzaton (optonal) – MSI Z77 MPOWER User Manual

Page 96

Advertising
background image

B-16

Intel RAID

RST Synchronzaton (optonal)

If you are usng Maxmzed mode as the Acceleraton mode, the data on the hard dsk

s not always synchronzed wth the data n the SSD cache. In some stuatons, you may

want to manually sync the dsks for avodng data loss.

Follow these steps to sync manually.

Reboot system, durng the Power-On Self Test (POST) press, press <Ctrl> and <I>

keys smultaneously to enter the Intel Rapd Storage Technology Opton ROM.
Select opton 5 “Acceleraton Optons” and press <Enter> key. The followng screen

appears.

1.

2.

[ ]

ACCELERATION OPTIONS

[ ]

HELP

Name

Press 's' to synchronze data from the cache devce to

the Accelerated Dsk/Volume.

Press 'r' to remove the Dsk/Volume Acceleraton.

WARNING:

IT IS RECOMMENDED THAT YOU [ERFORM A SYNCHRONIZATION

BEFORE REMOVING ACCELERATION.

[ ↑↓] - Select [ESC] - Prevous Menu

Type

Capacty

Status

DISK PORT 0

Non-RAID Dsk

153.4GB

Mode

Maxmzed

No Sync

Press <S> to synchronze data.

3.

[ ]

ACCELERATION OPTIONS

Name

Type

Capacty

Status

DISK PORT 0

Non-RAID Dsk

153.4GB

Mode

Maxmzed

In Sync

DISK / VOLUME INFORMATION

[ ]

5. Ext

SYNCHRONIZING THE DATA MAY TAKE SEVERAL MINUTES.

DO NOT INTERRUPT THE PROCESS!

[ ]

SYNCHRONIZATION VERIFICATION

Are you sure you want to synchronze data to
"DISK PORT 0"? (Y/N):

When prompted, press <Y> to confirm.

4.

Once synchronzaton s complete, the status wll change to In Sync.

5.

Advertising