SECTION VII

ELECTRICAL SERVICE SPECIFICATIONS

NOTE: Contact the factory for electrical information not listed.

NOTE: ADC reserves the right to make changes in specifications at any time without notice or

obligation.

ADG-27 (Gas)

IMPORTANT: 208 VAC and 230/240 VAC ARE NOT THE SAME.

When ordering, specify exact voltage.

NOTES:

A.

Fuse ratings are dual element time delay current limiting, class
RK1 or RK5

ONLY.

B.

Circuit breakers are thermal magnetic (industrial) type

ONLY.

For others, calculate/verify correct breaker size according to

appliance amp draw rating and type of breaker used.

C.

Circuit breakers for 3Ø dryers

must be 3-pole type.

Service

Voltage

Phase

Wire

Service

Approx.

Amp

Draw

Fusing

Dual Element

Time Delay

Circuit

Breaker

115

2

9.6

---

20

208

2

5.0

---

15

230/240

2

5.3

---

15

208

3

3.0

---

15

230/240

3

3.2

3.6

15

460

3/4

2.1

2.5

15