To reset the AXIS 243SA to the original default settings, go to the System Options >

Maintenance web page (described in Maintenance, on page 56) or use the control button

on the Axis video server, as described below:

Using the Control Button
Follow the instructions below to reset the AXIS 243SA to the factory default settings using

the Control Button.

1. Switch off the Axis video

server by disconnecting

power.

2. Press and hold the Control

Button while reconnecting the

power.

3. Keep the Control button

pressed until the Status

Indicator displays yellow (this

may take up to 15 seconds).

4. Release the Control Button.
5. When the Status Indicator changes to Green (may take up to 1 minute), the

process is complete and the Axis video server has been reset.

6. Re-install the Axis video server, as described in the Installation Guide.