Lenovo ThinkServer RD530 User Manual

Page 31

Advertising
background image

3

NIC 1 status LED

4

NIC 2 status LED

The two NIC status LEDs indicate the LAN status for the Ethernet connector 1 and Ethernet connector 2
on the rear panel of the server.

NIC status LED

Color

Description

On

Green

The server is connected to a LAN.

Off

None

The server is disconnected from a LAN.

Blinking

Green

The LAN is connected and active.

5

System error LED

The system error LED helps you to determine if there are any system errors.

System error LED

Color

Description

Action

The temperature of the server reached
the non-critical temperature threshold.

• Check the BMC for errors and check

the system fans.

• Ensure that the ambient temperature

limit LED is off.

The voltage of the server reached the
non-critical voltage threshold.

Replace the system board.
Note: This procedure must be performed
only by trained service personnel of
Lenovo. See Chapter 8 “Getting
information, help, and service” on page
145
.

A fan has been detected to be running at
low speed.

Check the system fans.

A hot-swap fan has been removed.

1. Ensure that the system fans are

connected securely to the system
board.

2. Reinstall the removed fan or install a

new fan to replace the removed fan.

The power supply has a critical error.

Check the BMC for detailed information.

The power cord has been disconnected
from one power supply or a redundant
power supply has been removed.

1. Ensure that the power supplies are

installed securely in the server.

2. Ensure that the power cords are

connected securely to the power
supplies.

3. Install a new power supply to

replace the removed one.

On

Amber

The THERMTRIP# signal is asserted
because the system is overheated.

• Check the BMC for errors and then

check the system fans.

• Ensure that the ambient temperature

limit LED is off.

Off

None

The server is off or the server is on and
is working correctly.

Chapter 3

.

Product overview

19

Advertising