Alamo JD-5225 User Manual

Page 45

Advertising
background image

© 2005 Alamo Group Inc.

Section 5 - 7

Switch Blade (JD-5105-5205-5225-5325-5425-5525, Asy. Man) 05/05

Female Threaded

Plunger Rod

Conduit Sleeve

Cross-

Screw Hole

Threaded Bead

Figure 15

Figure 14

Figure 16

1.

First remove the Cross- Screw from the

bottom of the Control Stick Assembly. DO NOT
remove the screws that fasten the two housings
halves together (See Figure 13).

2.

Next holding the housing, fully shift the

Handle in the Control Stick Assembly to expose
the female-threaded end of the Plunger Rod (See
Figure 14).

3.

Then while holding the Handle to expose

the Plunger Rod, thread the Threaded Bead of
the Cable into the end of the Plunger Rod and
tighten securely. Release the Handle, allowing
the Cable to pull into the Control Stick Assembly
(See Figure 15)

4.

Once Cable is attached to Plunger Rod,

move the handle to pull conduit sleeve up and
into the control stick assembly (See Figure 16)
The Conduit Sleeve has a groove in it that should
align with the cross screw (See Figure 16)

5.

Reinstall the Cross Screw making certain

that the cross screw and conduit sleeve groove
are in alignment. Tighten the cross screw
securely (See Figure 17)

Control Stick

Assembly

Cross-Screw

Figure 13

Control Cable Connection to Control Stick Assemblies:

Control Valve & Valve Controls Installation - Remote Cables

Advertising