Follow the procedure below to measure a color chart and create a
profile using the Konica Minolta FD-5 spectrodensitometer.

1. From the Tools menu, select Profiling Tool.

2. Select Print and measure chart.

3. Click Next.

4. Perform the following actions:

a. In the Measuring device list, select the FD-5

spectrodensitometer as the measuring device that you will
use to measure the color chart.

b. In the Warm up copies box, select the number of copies of

the warm-up file that you want to print.

c. In the Tray list, select the tray in which the paper stock for

which you want to create a profile is loaded.

d. In the Screening list, select the screening method for the

profile.

e. In the Calibration list, select the relevant calibration table.

Latest is the default setting (highly recommended).

f. In the Number of copies box, select the number of copies

of the chart that you want to print.

5. Click Print.

The color measurement chart and the warm-up file are
printed.

6. Place the color measurement chart on a clean flat surface.

7. Click Measure and perform the following actions.

a. Place the ruler on the chart and align the opening to the

first row of the chart indicated by the arrow in the wizard
screen.

b. Place the instrument's two feet in the ruler grooves and

align the specimen measuring port with the position where
it touches the ruler's opening (on the left side of the ruler).

c. Press the measuring button.

After approximately 1 second the device beeps.