Warning, Control and auxiliary equipment – Allstar Products Group MVP-SQ User Manual

Page 14

Advertising
background image

F. Using two (2) wire nuts (supplied), connect the
wire ends at the SAFE FINISH™ Photosystem
receiver to the pigtail wire ends coming out of the
receiver unit. Although not required, it is
recommended to connect the trace wire ends together
and the unmarked wire ends together.

STEP 4 :

Final Installation

A. Attach the"U" brackets to the "L" brackets with a

1/4-20 carriage bolt, washer and hex nut (provided).
Insert the bolt from the inside of the "U" bracket and
hand tighten only at this time.

B. Place the

transmitter and
receiver units
into their
respective "U"
brackets. See
Illustration, at
right.

C. Connect the

interconnect wire
pair to the garage
door opener
terminals marked
"1" & "4". Although not required, it is suggested
that the "trace" be connected to Terminal 4. See
Wiring Diagram, Page 19.

Tighten all mounting screws and bolts. Final
alignment and the system test is covered on Page 17,
Step 5 “E: Operation and Adjustment Instructions.

AN AUTOMATIC GARAGE

DOOR SYSTEM POSES A

THREAT OF INJURY OR

EVEN DEATH. INSTALL

THE SAFE FINISH

PHOTOSYSTEM NO

HIGHER THAN 6” ABOVE
THE GARAGE FLOOR TO

REDUCE THE RISK TO

SMALL CHILDREN.

WARNING

PRE-POWER ON-

INSTALLATION CHECKLIST

Before continuing with the operation and
adjustment section, make sure that
:

1. The front and rear mounts for the opener are

sound and secure and the rail is positioned

correctly above the high arc of the door, and that

the opener is positioned over the door action

centerline.

2. For sectional door and one piece door with

tracks, the position of the door arm (with the

door closed), is such that it’s connecting point on

the trolley is 5” to 8” behind it’s connecting

point on the door bracket. The door arm should

never be perfectly vertical when the door in in

the closed position.

3. The Manual Release Label and cord are secure

to the Manual Release Lever. The handle is

located 6 FT above floor level and requires no

more than a 50 pound pull to activate. The

trolley and the release mechanism are properly

lubricated.

4. The standard wall push button or the Super

Station (deluxe wall push button station) is in

such a position and of such a height that it can

only be actuated by an adult of average height.

The Control Button Warning label is

prominently displayed next to the push button or

wall station.

5. All wiring is correct to codes or better. There is

ground continuity form the supply. The ground

prong on the power cord is intact.

6. All ropes have been removed from the door.

The door moves freely without binding when

raised or lowered manually. The door is

correctly balanced and lubricated. All door

hardware is secure and sound. The sensitivity

has been adjusted to minimum force for the

application.

7. The door reverses on obstructions to within 1.5"

of the floor. The concrete or other surface

beneath the closed door provided uniform

contact.

8. The plastic envelope for this manual is attached

to the wall near the push button or wall station

and this manual is placed there for owner use

and reference.

9. On door with extension type counterbalance

springs, restraint cables have been placed

through the springs.

10. There is Ground Fault Interruption (GFI)

protection of the power line to the opener or in

the receptacle.

11. On doors with adjustable bottom edges, edges

have been locked after adjustment.

104383

CONTROL AND AUXILIARY EQUIPMENT

14

Advertising
This manual is related to the following products:

MVP