STEP 1:

Testing the Limit Settings: To check the Limit Settings, start

the Opener by pushing the standard wall Push Button or Super Station. Be
prepared to activate the button again quickly - per the Operating
Parameters outlined above - or if you see that the door is going to over
travel. As illustrated above, move the Cams toward the Power Unit to
DECREASE door travel and toward the Front Idler to INCREASE door
travel. Adjust the Up Limit Cam so that the door comes to rest where it
normally would without an electric Opener. Adjust the Down Limit Cam
so that the door closes firmly without putting undue stress on the Door
Arm. At full closed position, the door arm assembly should compress
approximately one inch.

STEP 2:

Adjusting the Sensitivity Force —

Sensitivity System force adjustment screws are located
on the side rails of the Power Unit and can easily be
adjusted with a screwdriver. Turn the screws
CLOCKWISE for more force and
COUNTERCLOCKWISE for less force.

STEP 3:

Testing the Sensitivity Force — To test the

Sensitivity System, start the Opener and grasp the
bottom door handle halfway through the door's travel
(opening or closing). When testing in the CLOSE
direction, a second person will be needed to maintain
pressure on the Push Button IF an Auxiliary Entrapment
Protection Device has not yet been fitted. If a second
person is
unavailable, use a
stiff cardboard
carton placed in the
door's downward
path to indicate the
force the Opener is

exerting. If the force adjustment screws are properly set,
the door should stop if opening, and reverse if closing
without exerting undue pressure.

STEP 4:

Testing the Opener’s Reversing System —

To test the Opener's Reversing Feature at floor level,
place a solid object at least 1-1/2" thick (such as a
standard 2 X 4 board laid flat) on the ground where the
center of the door will contact it. Close the door. If the

OPEN
FORCE
ADJUSTMENT

CLOSE FORCE

ADJUSTMENT

104391

108407

IF LIMITS ARE NOT

ADJUSTED

PROPERLY, THE

EMERGENCY RELEASE

MECHANISM MAY NOT

WORK PROPERLY AND

DOOR OPERATION

COULD

RESULT IN DOOR

DAMAGE, SERIOUS

PERSONAL INJURY OR

DEATH!

WARNING

W A R N I N G

IMPROPER ADJUSTMENT OF

SENSITIVITY SYSTEM FORCE COULD

CAUSE ENTRAPMENT, INJURY OR

DEATH. SET ADJUSTMENTS FOR JUST

ENOUGH FORCE TO OPERATE THE

DOOR RELIABLY, BUT NO STRONGER.

Contact a service professional to

correct any binding, sticking or other

door problems. DO NOT OVER-ADJUST

SENSITIVITY SYSTEM TO

COMPENSATE FOR A POORLY

WORKING DOOR.

OPERATION AND ADJUSTMENT INSTRUCTIONS

16

THE SENSITIVITY SYSTEM REVERSING TEST

SHOULD BE PERFORMED MONTHLY TO

ENSURE THAT THIS IMPORTANT SYSTEM

REMAINS IN PROPER ADJUSTMENT.

W A R N I N G

Advertising
This manual is related to the following products:

MVP